Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female

Still deciding? Get samples of $ !
Request Sample
Product Details
Customization: Available
Type: Antenna Feeder Arrester
Structure: Protective Gap
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (21)
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female pictures & photos
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female pictures & photos
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female pictures & photos
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female pictures & photos
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female pictures & photos
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female pictures & photos
  • Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
  • Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
  • Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
  • Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
  • Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
  • Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female

Find Similar Products

Overview

Basic Info.

Model NO.
NL-SPD02-2206019
Installation
Parallel Arrester
Application
AC/DC System
Size
Small
Operation Voltage
Low Voltage
Shape
Spiral
Material
Brass,Ternary Alloy Plated
Certification
ROHS, ISO9001,CE
Brand
Nalei/ODM/OEM
Model
1/4λ-DIN-Jk0727-L65-O01
Interface Way
DIN Female to Dln Male
Impedance
50 ω
Frequency Range
0.7-2.7 GHz
Insertion Loss
≤ 0.2dB
Vswr
≤ 1.25
Nominal Discharge Current(in)(8/20μS)
≥ 25ka
Maximum Discharge (Imax)(8/20μS)
≥ 60ka
Response Time (Ta)
≤ 1ns
Maximum Transmit Power (Ptmax)
200W
Salt Spray Test
≥ 48h@Neutral
Transport Package
Carton
Specification
1/4λ -DIN-JK0727-L65-O01
Trademark
Nalei/ODM/OEM
Origin
China

Product Description

Product Parameters

 

Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
Preferred Materials,Compliant with Standards
Precision Machining,Process Specification
Factory Inspection,Stable Performance

1.Pure Brass is used as the Substrate, and the Shell is Treated with Nickel Plating, Which has Good Wear Resistance.

2.Body:Brass,Ternary alloy plated.

3.Inner Contact:Copper,Gold plated.

4.Insulator:PTFE.
Whole Process Product Quality Control

1.It can be Customized According to Customer Application Scenarios.

2.Temperature Range (-40ºC~+85ºC@Altitude ≤4Km).

3.Salt Spray Test (≥48H@Neutral).

4.Waterproof Class (IP68).

5.Implementation of the Standard (IEC 61643-21,IEC 60169-4).
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
 
Industry-specific Attributes
Type Lightning Arrester
Applicaton RF, Microwave
Origin Nanjing,China
Certification ISO9001,ROHS,CE
Customization Available
Trademark nalei
Product Description
Product Name Coaxial RF Surge Protection Device 1/4λ-DIN-JK0727-L65-O01
Model 1/4λ-DIN-JK0727-L65-O01
Material and Plating
Body Brass,Ternary alloy plated
Inner Contact Copper,Gold plated
Insulator PTFE
Electrical Characteristics
Impedance 50 Ω
SPD Type 1/4λ
Protection Circuit DC Block
Interface Way DIN Female to DlN Male
D/C 0.7-2.7 GHz
Frequency  Range 0.7-2.7 GHz
Insertion Loss ≤ 0.2dB
VSWR ≤ 1.25
Nominal Discharge Current(In)(8/20μs) ≥ 25KA
Maximum Discharge (Imax)(8/20μs) ≥ 60KA
Response Time (Ta) ≤ 1ns
Maximum Transmit Power (Ptmax) 200W
PIM3(2X43dBm) ≤ -155dBc
Voltage Protection Level 15V
Insulator Resistance ≥ 5000MΩ
Relative Humidity 30%~90%
Temperature Range -40ºC~+85ºC@Altitude ≤ 4Km
Ground Resistance Ω / Wire Diameter ≤ 4Ω/≥ 2.5mm²
Environmental and Mechanical Specifications
RoHS Compliant
Waterproof Class IP68
Thermal Shock IEC 60068-2-3
Vibration IEC 60068-2-6
Salt Spray Test ≥ 48H@Neutral
Implementation of the Standard IEC 61643-21,IEC 60169-4
Product Display


Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female

Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
 
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
  

Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female

Packaging & Shipping

 

Packaging & Delivery
Transport Package BOX / Carton
Package Size (For Reference Only) 30.00cm * 20.00cm * 8.00cm
Package Gross Weight (For Reference Only) 0.500kg
Production Capacity  10000 Piece/Pieces Per Week
Port NANJING/SHANGHAI,CHINA

Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female
Company Introduction


Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female

 

Certifications


Nalei 800-2500MHz 1/4 Wavelength Mode Corrosion Resistance Lightning Surge Arrester Protector Coaxial RF Surge Protection Device with DIN Male to Female

FAQ

 

Frequently Asked Questions
Q:  Can you do our Designs (OEM)?
A:  lf you have special requirements, welcome to contact us for more details. we can communicate all your reasonable requests honestly.

Q: Is the Price Negotiable?
A: Yes, It is negotiable, but it is subject to your order quantity.

Q: What's the MOQ (Minimum Order Quantity)?
A: Generally speaking 10pcs, but it depends on models.

Q. It is all Right to Add our Logo on your Products?
A: Yes, we can do printing logo or laser logo.

Q: Can you Send Samples to us for the Test?
A: Yes, samples can be sent, Please contact customer service for specific details.

Q: How about your Delivery Time?
A: Generally, it will take 7 to 35 days after receiving your advance payment. The specific delivery time depends on the item and quantity of your order.

Q: Do you Test all your Goods Before Delivery?
A: Yes, we will do a final inspection of the goods before delivery.

Q: How do you Give me your Goods?
A: By air, shipping by sea, truck by DHL, TNT, UPS, FEDEX. Choose the best shipment method according to the actual situation.

Q: Can you Produce According to the Samples?
A: Yes, we can produce your samples or technical drawings. We can build the molds and fixtures.

Q: What is your Sample Policy?
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.

Q: What Payment Methods do you Accept?
A: We accept all payment methods including PayPal, T/T, Credit Card, Western Union, and Bank Transfer. Please contact us for more details. But if you have different requirements, we may discuss them together.

Q. Does the Product Meet the Local Customs Clearance Standards?
A: Our products have been sold in large quantities all over the world, and all products have passed the relevant certifications recognized by the local government. In addition, we provide standardized product information and packaging to ensure full compliance with local customs clearance requirements.

If you have special requirements for customs clearance in your local area, please contact us before placing an order, we can provide timely and effective assistance.

Send your message to this supplier

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now